Ross Revenge Plans Logo

Join Our Forum Sign in or REGISTER

Perkins 50kVA Generator

Ross Revenge Perkins 50kVA Generator

The Perkins 50kVA generator was installed as a result of the Starboard MAN 250 kVA generator falling into disrepair. Purchased with funds raised by the Radio Carolline Southampton Support Group, the Perkins 50kVA was delivered and installed whilst the Ross Revenge was berthed in Tilbury Docks in 2011.

PERKINS 50KVA (Phaser 1004) - SPECS
Engine Number YA
Engine Type 6 Clyinder Naturally Aspirated
Combustion System Direct Injection
Nominal Bore 100mm
Stroke 127mm
Compression Ratio 16.5:1
Cubic Capacity 6 Litres
Firing Order 1,5,3,6,2,4
Weight 600Kg - (1320 lbs)


The video below shows the arrival of the Perkins Phaser at Tilbury Docks, with Chief Engineer, Peter Clayton, and Alan Beech putting the set through its paces prior to installation in the hold Generator Room.